Please, insert a valid input in "Alarm on digin" field"
Parameters Value Description
Position Position of the cabinet in signed degreees eg. Amplex: '56.157,10.193'
These can be taken from, or entered into maps.google.com eg:
http://maps.google.com?q=56.157,10.193
Timezone Timezone of the cabinet. Only used for alarm texts: eg. 'CET-1CEST-2' See
http://en.wikipedia.org/wiki/Time_zone and
http://www.di-mgt.com.au/wclock/tz-syntax.txt
Sunrise offset Offset from sunrise in minutes to turn light off eg. '-30'
Sunset offset Offset from sunset in minutes to turn light on eg. '30'
Alarm on digin Set to 1 or 2 (normally open) if eg. a door switch is wired to digital_in
Alarm on digin text Text to send when digital in alarm triggers
Doorswitch on phase4 Set to 1 if a door switch operated lamp (230V) is wired to phase_4
Phases wired A comma separated list of phase inputs to monitor (1-3) eg. 1,2,3
Photocell digital Set to 1 if a digital photocell is wired to digital_in (closed when lit)
Photocell threshold Set to lux threshold if a ServoDan 43-198 photocell is wired to analog_in_1
Photocell active zone Number of minutes before sunrise/sunset the photocell is enabled
Currentsensor wired A comma separated list of wired current coils (1-6) eg. '1,2,3'
Leakage threshold Set maximum leakage in mA if a leakage sensor coil is wired
Alarm telno Comma separated list of phone numbers to receive alarms about:
Trusted_telno Comma separated list of phone numbers allowed to control the cabinet.